Every litre of bottled cooking oil on a supermarket shelf has passed through a refinery, and the last and most demanding stage of that refinery is powered by heat. Degumming, neutralization, bleaching and above all deodorization each hold oil at a controlled temperature, and the deodorizer runs at 240 to 260 degrees Celsius for hours at a time. Plants that try to reach this temperature with steam need medium pressure steam around 4 MPa, a wholly different class of boiler plant, while a thermal fluid system reaches the same temperature on a loop rated at less than 1 MPa. This article maps the heat users of a typical edible oil refinery, compares thermal fluid against medium pressure steam, and walks through a complete sizing example on the YY(Q)W oil/gas fired thermal fluid heater range.
The method applies to a continuous physical or chemical refinery of 100 to 500 tonnes of crude oil per day and scales to batch plants. The figures are realistic engineering estimates for planning; a final selection should always be confirmed with a heat balance based on the actual oil throughput, deodorizer design and heat recovery arrangement of the project.
A refinery takes crude oil through a fixed sequence. Degumming hydrates phospholipids at 70 to 90 degrees Celsius. Neutralization or physical refining removes free fatty acids at 60 to 90 degrees Celsius. Bleaching mixes oil with adsorbent and holds it around 105 to 110 degrees Celsius under vacuum, then filters the clay out. Deodorization then strips volatile compounds from the oil at 240 to 260 degrees Celsius under deep vacuum, usually with injected stripping steam, and a heat recovery section preheats incoming oil against the hot finished product. Winterization, when required, chills rather than heats.
Two of these stages decide the heat supply design. The deodorizer is the single largest and hottest user: it must raise a large flow of oil from roughly 110 degrees Celsius after bleaching and heat recovery to full stripping temperature, then hold that temperature against stripping steam generation, vacuum system losses and radiation for every hour of production. And its temperature is not negotiable: below about 230 degrees Celsius stripping efficiency falls away and flavour stability suffers, while the equipment is designed to hold oil below 270 degrees Celsius to protect product quality and oil life. A heat source that can deliver 250 degrees Celsius continuously, at low pressure and with close control, matches the process almost exactly.
The table below lists the hot users of a mid sized continuous refinery of about 200 tonnes per day. Temperatures follow common industry practice; each project shifts them slightly, but the structure of the load is remarkably consistent across the industry.
| User | Operating temperature | Load character | Consequence of a shortfall |
|---|---|---|---|
| Degumming and hydration | 70 to 90 degrees Celsius | Steady holding during production | Incomplete phospholipid removal, dark oil |
| Neutralization and soapstock section | 60 to 90 degrees Celsius | Batch heating plus holding | Poor separation, high refining loss |
| Bleaching section | 105 to 110 degrees Celsius under vacuum | Continuous flow heating and drying | Residual moisture, weak colour removal |
| Deodorizer feed heating | 110 to 250 degrees Celsius rise | Continuous, largest single duty | Stripping temperature not reached, flavour defects |
| Deodorizer holding | 240 to 260 degrees Celsius | Stripping steam generation and radiation | Temperature sag during throughput changes |
| Storage tank heating and line tracing | 45 to 60 degrees Celsius | Continuous, weather dependent | Solidified oil, blocked lines at start up |
| CIP hot water and utilities | 60 to 80 degrees Celsius | Intermittent | Cleaning quality, sanitation compliance |
| Building heat | 45 to 70 degrees Celsius circuits | Winter load | Comfort only |
Note what the list does not contain. Nothing in the refinery needs steam as such: bleaching and deodorization run under vacuum with their own vacuum plant, and stripping steam is raised inside the deodorizer from the hot oil itself. The demand is for hot oil at a controlled high temperature, which is precisely what a thermal fluid heater produces.
Many refineries were originally built around a medium pressure steam boiler, and the replacement question deserves a direct answer. To hold 250 degrees Celsius with saturated steam, a plant needs about 4 MPa of steam pressure, which brings code vessels, licensed attendants and expensive pipework. The comparison below reflects what the two systems actually do on a refinery duty.
| Aspect | Medium pressure steam plant | YY(Q)W thermal fluid heater |
|---|---|---|
| Pressure to reach 250 degrees Celsius | About 4 MPa saturated steam | 0.8 to 1.0 MPa on the oil loop |
| Regulatory burden | High pressure code plant with certified operation | Low pressure loop monitored by level, temperature and differential pressure |
| Condensate and trap losses | Traps, flash steam and condensate losses commonly waste 10 to 20 percent of generated heat | Closed loop with no condensate; losses are insulation only |
| Water treatment | Full treatment, dosing and blowdown at 4 MPa quality | Oil is tested, not replaced by a treatment plant |
| Temperature control | Pressure and control valve cascades near saturation | Oil supply temperature set directly and held within a few kelvin |
| Footprint and piping | Heavy wall steam mains and condensate returns | Standard wall oil piping, smaller bore |
The practical outcome seen repeatedly in conversions is a fuel saving in the range of 10 to 20 percent simply from removing trap and condensate losses, before any burner efficiency gain is counted. The safety argument matters as much: replacing 4 MPa steam with a sub MPa oil loop removes an entire class of hazard from the refinery utility block.
The YY(Q)W is a horizontal, coil type thermal fluid heater firing natural gas, liquefied petroleum gas, light oil or heavy oil. The coil accepts the radiant and convective heat of the burner flame, a circulating pump drives the oil through the loop, and the burner modulates to hold the set oil supply temperature. Design data for the range are: rated heat power from 20 to 600 x 10,000 kcal/h (approximately 0.23 to 7.0 MW), rated working pressure 0.8 to 1.0 MPa on the oil circuit, and maximum working oil temperature of 300 degrees Celsius with mineral oil or 320 degrees Celsius with synthetic fluid, comfortably above the 240 to 260 degree deodorization window.
| Model | Rated power (10,000 kcal/h) | Approx. output (MW) | Working pressure (MPa) | Max oil temperature | Typical duty served |
|---|---|---|---|---|---|
| YYQW-30 | 30 | 0.35 | 0.8 | 300 / 320 C | Batch refinery, pilot plant |
| YYQW-60 | 60 | 0.70 | 0.8 | 300 / 320 C | Small continuous line |
| YYQW-120 | 120 | 1.40 | 0.8 | 300 / 320 C | Up to about 150 tonnes per day |
| YYQW-200 | 200 | 2.33 | 0.8 | 300 / 320 C | About 200 tonnes per day refinery |
| YYQW-300 | 300 | 3.49 | 1.0 | 300 / 320 C | Large refinery plus fractionation |
| YYQW-400 | 400 | 4.65 | 1.0 | 300 / 320 C | Integrated crushing and refining site |
| YYQW-600 | 600 | 6.98 | 1.0 | 300 / 320 C | Multi plant utility block |
Models between these points cover the full 20 to 600 span, so a selection rarely has to compromise by more than a few percent. The same platform serves the drying, press and chemical duties listed on the food and beverage application pages, which matters for crushers that refine their own oil and also run seed drying or lecithin plants on one site: one heater family, one oil chemistry and one maintenance routine can cover all of them.
Walk the refinery and record for every user its oil or water flow, operating temperature and duty pattern. Mark the deodorizer carefully: its feed heating duty depends on how much heat recovery the deodorizer design includes, and the holding duty depends on stripping steam rate and vacuum plant losses.
Feed heating is oil mass flow times specific heat of about 2.2 kJ per kilogram per kelvin times the temperature rise, divided by production hours. This term usually dominates the whole plant, and it is the reason a refinery heat supply should be sized around the deodorizer rather than around the small tanks.
Steady holding on the deodorizer covers stripping steam generation, vacuum system losses and radiation; the bleaching section, batch tanks, storage heating, line tracing and CIP water add the rest. Storage tank heating is easily underestimated in cold climates, where oil at 50 degrees Celsius must be maintained in every tank and traced line around the clock.
Not every user peaks at once, so apply a demand factor of 0.8 to 0.85 to the connected load, then add 10 to 15 percent margin for fouling of exchange surfaces and future throughput growth. Select the model whose rating puts the running point at roughly 65 to 80 percent of nominal, which keeps the burner modulating rather than cycling and leaves reserve for higher deodorization temperatures on specialty oils.
Take a refinery running 20 hours per day at 200 tonnes of crude oil throughput, with a deodorizer fed at 110 degrees Celsius after heat recovery and stripping at 250 degrees Celsius.
| Load | Basis | Demand |
|---|---|---|
| Deodorizer feed heating | 200,000 kg x 2.2 kJ/kgK x 140 K over 20 h | 860 kW |
| Deodorizer holding | Stripping steam generation, vacuum and radiation | 250 kW |
| Bleaching section | 200,000 kg x 2.2 x 20 K over 20 h, plus losses | 120 kW |
| Degumming and neutralization tanks | Batch warm up and holding | 180 kW |
| Storage tank heating and line tracing | Continuous, moderate climate | 100 kW |
| CIP hot water and miscellaneous | Allowance | 60 kW |
| Connected load | 1,570 kW | |
| Diversity at 0.85 | 1,570 x 0.85 | 1,335 kW |
| Margin at 15 percent | 1,335 x 1.15 | 1,535 kW design output |
| Model selection | YYQW-200 at 2,326 kW | About 66 percent load; YYQW-120 at about 110 percent is rejected |
YYQW-200 lands the running point comfortably below 70 percent at commissioning, holds 250 degrees Celsius on the deodorizer through throughput changes, and leaves reserve for a future fractionation column or a second deodorizer line. Where capital is tight, a configuration of two smaller heaters in parallel is worth pricing: it gives redundancy for the deodorizer, which is the stage a refinery least wants to lose, and lets one unit cover holding and storage loads alone during short production breaks.
Hot oil never touches the product. The oil loop stays in the utility block and transfers heat either directly into the deodorizer heating coils or through stainless steel heat exchangers into secondary circuits, one per temperature group: a high temperature circuit for the deodorizer, a medium circuit at 110 degrees Celsius for bleaching, and low temperature circuits for tanks, tracing and CIP water. Each zone is regulated by a control valve, so a batch tank coming on line does not disturb the deodorizer temperature.
Mineral based heat transfer oils rated for 300 degrees Celsius cover the standard duty, and synthetic fluids rated for 320 degrees Celsius are used where higher setpoints are wanted. Because oil and product are separated by heat exchanger walls or coil walls at every point, the food safety question is one of construction and discipline rather than contact: use exchangers and coils built for edible plant service, keep the loop leak free with differential pressure monitoring, and document the system so auditors can see that no heat transfer fluid pathway connects to the oil stream.
A deodorizer discharges oil almost as hot as it strips it, and most modern deodorizers recover that heat into the feed stream internally. Where the deodorizer design leaves recovery external, the thermal fluid loop can serve a feed economizer, and flue gas recovery on the heater itself returns further fuel. A plant that skips recovery pays for it in fuel every production hour, so the sizing conversation with the heater supplier should always include it.
The YY(Q)W burns natural gas, liquefied petroleum gas, light diesel or heavy fuel oil, with the burner and fuel skid configured for the fuel available on site. Consumption figures below are planning values for one megawatt hour of useful heat delivered at a typical thermal fluid heater efficiency of about 85 percent; actual figures depend on fluid temperature setpoint, fuel calorific value and maintenance condition.
| Fuel | Approximate consumption per MWh useful heat | Practical notes |
|---|---|---|
| Natural gas | About 120 Nm3 | Cleanest flue gas, lowest maintenance burner duty |
| LPG | About 92 kg | For sites beyond the gas grid; tank and vaporiser required |
| Light diesel | About 100 kg | Good standby fuel, easy storage |
| Heavy fuel oil | About 106 kg | Needs heating and tracing of the fuel line |
For the worked example, a two shift production day consumes roughly 20 megawatt hours of heat, which is about 2,400 cubic metres of natural gas per production day, or some 700,000 cubic metres per year at that schedule. Where piped gas is unavailable and LPG is expensive, the YGL biomass fired thermal fluid heater offers the same coil type design on wood chip, pellet, rice husk or palm kernel shell fuel, and many refineries located at crushing mills sit exactly where that fuel is cheapest.
Place the heater in a dedicated bay of the utility block with clear access for burner service on the front and coil inspection access as the manufacturer specifies. The expansion tank sits at the highest point of the oil system and should be sized at roughly one third of the total system oil volume; a cold oil drain tank sized for the full charge completes the layout. Route insulated oil piping to the deodorizer and secondary exchangers on a common rack, and keep hot surfaces guarded or insulated to a safe touch temperature.
The standard protection set includes oil outlet temperature control with a high limit, differential pressure monitoring across the coil against flow failure, low oil level cut out on the expansion tank, flame supervision on the burner and a commissioned safety relief arrangement on the loop. Train operators on two rules above all: never start the circulating pump against a cold, thick oil without following the warm up procedure, and never stop circulation while the burner is firing. Commission the high temperature trip against a real setpoint test before the first production run.
| Interval | Task |
|---|---|
| Daily | Log oil supply and return temperatures, expansion tank level, differential pressure, burner modulation |
| Weekly | Check circulating pump seals and noise, clean burner fan and flame sensor, test safety cut outs |
| Monthly | Inspect insulation and pipe supports, verify control valve travel on each exchanger zone, review trace heating on storage lines |
| Quarterly | Take an oil sample for viscosity, total acid number and flash point; trend the results |
| Annually | Full burner service, coil and flue gas side inspection and cleaning, exchanger gasket check, recalibrate safety instruments |
Thermal oil life depends far more on how hot the film inside the coil runs than on the calendar. A refinery that keeps flow above the minimum, reacts to quarterly oil analysis and holds setpoints within the design band typically runs many years on one charge; a plant that lets the oil cook at the top of the range with low flow will replace fluid much sooner and should budget for that from the start.
A thermal fluid heater is a fuel burning, heat bearing appliance placed at the heart of a food grade process, and the supplier behind it should be able to prove more than a price. Henan Hengxin Boiler Co., Ltd. manufactures under a special equipment production licence and holds ISO9001 and ISO14001 certification, with 3A enterprise credit standing, and the certificates page lists the documents for review. Standard models ship from an established platform, and the company also builds to customer drawings and develops custom configurations for special fuels, unusual capacity points, skid mounted assemblies with circulation pumps and expansion tanks pre piped, and control integration with refinery SCADA. For a new refinery or a steam to thermal fluid conversion, providing the oil throughput, deodorizer data and utility block dimensions is usually enough for a factory proposal with layout, consumption estimate and delivery schedule.
Yes. The range is designed for maximum working oil temperatures of 300 to 320 degrees Celsius, so a 250 degree process setpoint sits well inside the design band with margin for the film temperature inside the coil. What matters for stable deodorizer temperature is steady loop flow and a modulating burner, both of which are part of the standard control package.
No. Heat reaches the product through deodorizer heating coils or stainless steel heat exchanger walls only, and the loop is monitored by differential pressure and level so any leak is detected early. The system is documented so that food safety audits can trace the full separation between heat transfer fluid and product oil.
The loop keeps circulating and the burner drops to a low fire holding setpoint, which keeps the deodorizer and storage tanks warm and makes the next start up fast. This standby duty is far cheaper than reheating a cold plant from ambient, and it is one of the quiet advantages of thermal fluid over steam, which often has to be blown down and restarted.
A short list is enough to start: crude oil throughput per day, deodorizer feed and stripping temperatures, heat recovery arrangement, the list of secondary users, the fuel available and its pressure, and utility block dimensions. With those figures the factory returns a model selection, layout drawing, estimated fuel consumption and delivery time, and confirms whether a standard model fits or a custom configuration is the better route.
The difference between a smooth conversion and a disappointing one almost always lies in the heat balance, not in the hardware. Measure what the deodorizer and the rest of the refinery really do, and let the sizing method above turn that into a model selection. Henan Hengxin Boiler Co., Ltd. supports exactly that process with application engineers who have sized thermal fluid systems across the food, chemical, wood and surface treatment industries, and the company welcomes drawings and data for custom development. Send the throughput, the deodorizer data and the site fuel details, and a sizing proposal with layout and consumption figures follows for review before any commitment is made.